Cooling Systems

Aerodyn Engineering designs and manufactures its own line of cooling carts. Our cooling carts will supply filtered coolant to the slip ring while in operation. Aerodyn Engineering’s cooling units are extremely reliable and are designed and manufactured with the highest quality components and craftsmanship available in the industry today. Magnetically coupled pumps are employed within our system to deliver the cooling fluid, with full user instruments showing flow rate and system pressures.
Aerodyn Engineering cooling systems are equipped with battery backup to assure continued operation in the event of a site power failure.
|
Specifications
|
|
| Pump | Magnetically Coupled Gear Pump |
| Flow Rate | 0-1 GPM |
| Tank | Stainless Steel, Five Gallon Capacity |
| Heat Rejection | 2,500 BTU/hr, Air/Fluid Heat Exchanger |
| Filtration | 5 Micron Sintered Stailess Steel Filter |
| Voltage | 100/220 VAC, 50/60 Hz |
| Power | Less than 700 Watts |
| Battery Back Up | Provides 30 Minutes Operation after AC Power Failure |
| Controls | On/Off (Can be Remote Controlled) |
| Pump On/OFF (Can be Remote Controlled) | |
| Flow Rate (Digital with Analog Output) | |
| Displays | Pump Pressure |
| Slip Ring Supply Pressure | |
| Flow Rate (Digital with Analog Output) | |
| Alarms | Low Flow |
| Low Tank | |
|
AC Power Failure
|
|
The cart is also fitted with multiple gauges to monitor pressures (pump and supply pressure) as well as flow rate with a digital readout. These systems also include electronics to alert the operator when the system is in a situation where the cooling cart falls below certain parameters (low flow, low tank, and AC power failure). The cooling cart can be controlled remotely, so the operator is be able to monitor the vitals and even manage the cart from a control room. In the case of on-site power loss, the battery backup will provide an additional 30 minutes of continuous running to protect the slip ring from heat damage by drawing from the built in five-gallon tank.Custom features are also available and offer coolant preheating, refrigeration, and network control/monitoring.